Types of facial radiofrequency and what each one is for

Coolfase / radiofrequency

Types of facial radiofrequency and what each one is for

The types of facial radiofrequency explained: monopolar, bipolar, multipolar, fractional and microneedling, with a concern-by-technology table.

Reviewed by Dr. Taiane Amorim, dermatologist
November 26, 2026 · 6 min read

Short answer

The types of facial radiofrequency differ by two criteria: how many poles the device uses (monopolar, bipolar or multipolar) and how the energy is delivered (continuously over the skin, fractionated into points or through microneedles). Monopolar reaches deeper layers and is used for skin laxity; fractional and microneedling radiofrequency work more on texture and scars.

The names get mixed up in ads and even on clinic websites, which sometimes call the same device “fractional” and “with cooling.” The two words refer to different things. This guide sorts out the terms so patients know what is being offered.

How radiofrequency heats the skin

Radiofrequency is a high-frequency electrical current. As it passes through the skin, it meets resistance, and that resistance turns the energy into heat. The target is the dermis, where the collagen fibers are: controlled heating contracts the existing fibers and stimulates the production of new collagen in the following weeks.

Three variables change the result from one device to another:

  • Depth: depends on the design of the electrodes and the frequency.
  • Surface protection: some devices cool the epidermis while heating underneath; others do not.
  • Delivery method: continuous, spread-out heat, or points of energy separated by intact skin.

A review published in the Brazilian journal Anais Brasileiros de Dermatologia made an observation that applies to all of them: device manuals cite dermal temperatures of 50 to 75 °C, but none of the studies reviewed measured this temperature in humans. Temperature figures in advertising should be read with caution.

Monopolar (Coolfase, Thermage)

In monopolar radiofrequency, the energy leaves a single electrode in the handpiece and returns through a return pad placed on the body. This setup takes the heat deeper, so it requires surface cooling to protect the epidermis. This is the category of Thermage, the most studied device in this group, and of Coolfase, the radiofrequency used at Clínica Armori.

Coolfase is presented by the manufacturer as monopolar radiofrequency with cooling technology. It is worth noting that “cooling” and “fractional” answer different questions: the first word describes how the surface is protected; the second, how the energy is distributed. A device is classified by both, and one does not replace the other. The comparison between the two monopolar devices is in Coolfase or Thermage.

Bipolar and multipolar

In bipolar devices, the current flows between two closely spaced poles on the handpiece itself, without a return pad. The Brazilian review explains that, in this system, the treatment depth is around half the distance between the electrodes. The heat is more superficial and more concentrated.

Multipolar devices use three or more alternating poles, spreading the energy over a larger area. Many devices used in aesthetics belong to these groups. The same review noted that several Brazilian-made devices analyzed had no cooling system, unlike the international ones.

Bipolar and multipolar are not “worse” than monopolar; they are different. They are usually used in multi-session protocols, with a more superficial effect.

Fractional and microneedling

Fractional means the energy is delivered in small points, leaving intact skin between them. This preserved skin speeds up recovery. The main effect is on the surface: texture, pores and small scars.

Microneedling radiofrequency is a variation of fractional radiofrequency in which microneedles deliver the radiofrequency directly into the dermis. A critical review published in 2021 brought together 42 higher-quality studies and found use in rejuvenation, acne scars, stretch marks and other indications. The authors observed that remodeling is slow and progressive, with improvement continuing up to six months later.

Microneedling radiofrequency should not be confused with traditional microneedling, which uses only the needles, without energy.

Which one suits which concern?

The choice starts with the concern, not the device. Some examples of the reasoning:

  • Facial skin less firm, contour starting to sag: monopolar radiofrequency or micro-focused ultrasound, depending on the depth of the problem. The comparison is in Liftera or Coolfase.
  • Uneven texture, pores and fine lines: fractional or more superficial technologies.
  • Acne scars: microneedling radiofrequency is one of the options studied, alongside other treatments.
  • Advanced skin laxity with excess skin: no radiofrequency replaces surgery. A review of radiofrequency devices makes it clear that they were not designed to replace surgical procedures.

Contraindications apply to all types: pregnancy, active lesions in the area and some diseases and medications are evaluated at the appointment before any recommendation.

Summary table

Type How the energy is delivered Relative depth Most common use
Monopolar One electrode in the handpiece and a return pad on the body Greater Mild to moderate skin laxity
Bipolar Current between two poles on the handpiece Less, about half the distance between the poles Firmness and texture, in a series of sessions
Multipolar Three or more alternating poles Less, spread over a larger area Superficial firmness and texture
Fractional Points of energy with intact skin between them Superficial to medium Texture, pores, fine scars
Microneedling Microneedles deliver the energy to the dermis Adjustable by needle depth Acne scars, stretch marks, rejuvenation

Frequently asked questions

Is spa radiofrequency the same as in-office radiofrequency?

The physics is the same, but power, depth, cooling and indications vary widely between devices. Under Anvisa rules, the registered manual of each device states which professionals may operate it. Higher-energy devices, such as monopolar ones, call for a medical evaluation to check for contraindications and determine whether the skin laxity can be treated without surgery.

Does radiofrequency slim the face?

The goal of facial radiofrequency is to improve skin firmness and texture, not to reduce facial fat. A firmer contour may look more defined, but that is different from slimming. When the concern is fat volume, the cause is evaluated at the appointment before choosing any technology.

Can it be done with filler?

Yes, when indicated and with an interval set by the doctor. A retrospective study of 1,040 patients who combined micro-focused ultrasound or monopolar radiofrequency with injectables found infrequent adverse events. Even so, the order and timing between procedures are decided case by case.

Book an appointment on WhatsApp

Content reviewed by Dr. Taiane Amorim, dermatologist — CRM-RJ 52.96176-0 · RQE 38836.

References

Dra. Taiane Amorim
Medically reviewed by

Dr. Taiane Amorim

Board-certified dermatologist (SBD) · CRM-RJ 52.96176-0 · RQE 38836. Sees patients at Clínica Armori, in Copacabana.

Take the next step: book your appointment

Our team answers on WhatsApp and finds the best time for you.